# HAMeter configuration
# Mount this file into the container at /config/hameter.yaml
general:
# 0 = continuous (recommended for always-on server)
sleep_for: 0
# RTL-SDR device index (0 = first/only device)
device_id: "0"
# rtl_tcp listens inside the container (don't change unless using remote SDR)
rtl_tcp_host: "127.0.0.1"
rtl_tcp_port: 1234
# DEBUG, INFO, WARNING, ERROR
log_level: INFO
mqtt:
# Unraid server IP (where Mosquitto runs)
host: "192.168.1.74"
port: 1883
user: ""
password: ""
base_topic: "hameter"
ha_autodiscovery: true
ha_autodiscovery_topic: "homeassistant"
client_id: "hameter"
meters:
# Electric Meter — Itron Centron C1SR
# ERT Radio Serial: 23040293 (NOT the billing number 2698881)
- id: 23040293
protocol: scm
name: "Electric Meter"
unit_of_measurement: "kWh"
icon: "mdi:flash"
device_class: energy
state_class: total_increasing
# Calibration: physical_meter_reading / raw_scm_value
# From PoC: 59669 / 516030 ≈ 0.1156
# TODO: take a simultaneous reading to confirm this multiplier
multiplier: 0.1156
# Gas Meter — uncomment after running --discover to find the ID
# - id: REPLACE_WITH_GAS_METER_ID
# protocol: scm
# name: "Gas Meter"
# unit_of_measurement: "ft³"
# icon: "mdi:fire"
# device_class: gas
# state_class: total_increasing
# multiplier: 1.0
# Water Meter — likely Neptune R900 protocol
# - id: REPLACE_WITH_WATER_METER_ID
# protocol: r900
# name: "Water Meter"
# unit_of_measurement: "gal"
# icon: "mdi:water"
# device_class: water
# state_class: total_increasing
# multiplier: 1.0