HAMeter
Read utility meters (electric, gas, water) via SDR and publish to Home Assistant over MQTT.
HAMeter uses an RTL-SDR dongle to receive wireless transmissions from ERT-equipped utility meters, decodes them with rtlamr, and publishes readings to Home Assistant via MQTT auto-discovery.
Features
- Reads SCM, SCM+, IDM, and R900 (Neptune) meter protocols
- Built-in calibration multiplier per meter
- Home Assistant MQTT auto-discovery — sensors appear automatically
- Three HA sensors per meter: calibrated reading, raw reading, last seen
- Discovery mode to find nearby meter IDs
- Fully configurable via Docker environment variables — no config files needed
- Smart defaults based on meter type (energy, gas, water)
- Supports up to 9 meters simultaneously
Requirements
- RTL-SDR dongle (tested with Nooelec RTL-SDR v5)
- 915 MHz antenna (or telescopic whip at ~8 cm for 900 MHz band)
- Docker host with USB access (tested on Unraid)
- MQTT broker (e.g., Mosquitto)
- Home Assistant with MQTT integration
Quick Start
1. Install Mosquitto MQTT Broker
Install via your Docker host's app store or:
docker run -d --name mosquitto -p 1883:1883 eclipse-mosquitto
2. Add MQTT Integration to Home Assistant
Settings → Devices & Services → Add Integration → MQTT
- Broker: your Docker host IP
- Port: 1883
3. Connect the SDR Dongle
Plug the RTL-SDR into a USB 2.0 port (USB 3.0 can cause interference).
Blacklist the kernel DVB driver so it doesn't claim the device:
# On Unraid (persists across reboots):
mkdir -p /boot/config/modprobe.d
echo "blacklist dvb_usb_rtl28xxu" >> /boot/config/modprobe.d/rtlsdr.conf
rmmod dvb_usb_rtl28xxu 2>/dev/null
# On other Linux:
echo "blacklist dvb_usb_rtl28xxu" | sudo tee /etc/modprobe.d/rtlsdr.conf
sudo rmmod dvb_usb_rtl28xxu 2>/dev/null
4. Run HAMeter
docker run -d \
--name hameter \
--restart unless-stopped \
--device=/dev/bus/usb \
-e MQTT_HOST=192.168.1.74 \
-e METER_1_ID=23040293 \
-e METER_1_PROTOCOL=scm \
-e METER_1_NAME="Electric Meter" \
-e METER_1_DEVICE_CLASS=energy \
-e METER_1_MULTIPLIER=1.0 \
hameter:latest
Your meter should appear in Home Assistant within a minute.
Configuration
All configuration is done via environment variables. No config file needed.
Required Variables
| Variable | Description |
|---|---|
MQTT_HOST |
MQTT broker IP address |
METER_1_ID |
Meter radio serial number (ERT ID, not the billing number) |
METER_1_PROTOCOL |
Protocol: scm, scm+, idm, r900, r900bcd, netidm |
Optional Variables
| Variable | Default | Description |
|---|---|---|
MQTT_PORT |
1883 |
MQTT broker port |
MQTT_USER |
(empty) | MQTT username |
MQTT_PASSWORD |
(empty) | MQTT password |
MQTT_BASE_TOPIC |
hameter |
Base MQTT topic |
METER_1_NAME |
Electric Meter |
Friendly name in HA |
METER_1_MULTIPLIER |
1.0 |
Calibration multiplier (see below) |
METER_1_DEVICE_CLASS |
energy |
HA device class — sets smart defaults |
METER_1_UNIT |
(auto) | Unit of measurement |
METER_1_ICON |
(auto) | HA icon |
METER_1_STATE_CLASS |
total_increasing |
HA state class |
SDR_DEVICE_ID |
0 |
RTL-SDR device index |
LOG_LEVEL |
INFO |
DEBUG, INFO, WARNING, ERROR |
Smart Defaults by Device Class
When you set METER_1_DEVICE_CLASS, the icon and unit are set automatically:
| Device Class | Icon | Unit |
|---|---|---|
energy |
mdi:flash |
kWh |
gas |
mdi:fire |
ft³ |
water |
mdi:water |
gal |
You can override any of these with the explicit METER_1_ICON or METER_1_UNIT variables.
Multiple Meters
Add meters using METER_2_*, METER_3_*, etc. (up to METER_9_*):
-e METER_1_ID=23040293 \
-e METER_1_PROTOCOL=scm \
-e METER_1_NAME="Electric Meter" \
-e METER_1_DEVICE_CLASS=energy \
-e METER_2_ID=55512345 \
-e METER_2_PROTOCOL=r900 \
-e METER_2_NAME="Water Meter" \
-e METER_2_DEVICE_CLASS=water \
Gaps are fine (e.g., meter 1 and 3 without 2).
Finding Your Meter ID
Your meter has two numbers:
- Billing number — printed on the faceplate (e.g.,
2698881). Don't use this. - Radio serial number (ERT ID) — transmitted over RF (e.g.,
23040293). Use this one.
To find the ERT ID, run HAMeter in discovery mode:
docker run --rm \
--device=/dev/bus/usb \
-e MQTT_HOST=localhost \
-e METER_1_ID=0 \
-e METER_1_PROTOCOL=scm \
hameter:latest --discover --discover-duration 120
This listens for all nearby meter transmissions for 2 minutes and prints a summary:
DISCOVERY SUMMARY — 12 unique meters found
============================================================
Meter ID Protocol Count Last Reading
--------------------------------------------------
23040293 SCM 8 519161
55512345 R900 3 12345678
...
Cross-reference the IDs with your physical meters to identify which is yours. Your meter will likely be the one with the highest count (since it's closest).
Calibration
The raw value from the meter's radio does not directly equal the reading on the meter display. You need a calibration multiplier to convert raw values to actual units (kWh, gallons, etc.).
How to Calibrate
Step 1: Read your physical meter
Go to the meter and write down the display reading. For example: 59,669 kWh
Step 2: Get the raw reading from HA
In Home Assistant, go to Developer Tools → States and find your meter's raw reading sensor. For example: sensor.electric_meter_raw_reading shows 516,030
Take both readings at roughly the same time so they correspond.
Step 3: Calculate the multiplier
Divide the physical reading by the raw reading:
multiplier = physical_reading / raw_reading
multiplier = 59669 / 516030
multiplier = 0.1156
Step 4: Set the multiplier
Set METER_1_MULTIPLIER=0.1156 in your Docker environment variables and restart the container.
Verifying Calibration
After setting the multiplier, the Reading sensor in HA should closely match your physical meter display. If it drifts over time, repeat the process to recalculate.
The Raw Reading sensor (shown as a diagnostic entity in HA) always shows the unconverted value, so you can recalibrate at any time without removing the multiplier first.
Why Is Calibration Needed?
ERT meters transmit a raw register value, not the displayed reading. The relationship between the two depends on the meter's internal configuration (Kh factor, register multiplier, number of dials). The multiplier accounts for all of these.
Home Assistant Sensors
Each configured meter creates three sensors in HA:
| Sensor | Example Entity | Description |
|---|---|---|
| Reading | sensor.electric_meter_reading |
Calibrated value (e.g., 59,669 kWh) |
| Raw Reading | sensor.electric_meter_raw_reading |
Unconverted register value (diagnostic) |
| Last Seen | sensor.electric_meter_last_seen |
Timestamp of last received transmission |
All three are grouped under a single device in HA with the manufacturer shown as "HAMeter".
Energy Dashboard
To add your electric meter to the HA Energy Dashboard:
- Go to Settings → Dashboards → Energy
- Under Electricity Grid, click Add Consumption
- Select
sensor.electric_meter_reading - Optionally set a cost per kWh
Building from Source
git clone https://github.com/your-username/HAMeter.git
cd HAMeter
docker build -t hameter:latest .
The Dockerfile is a multi-stage build:
- Go — compiles
rtlamrfrom source - C — compiles
rtl-sdr(librtlsdr + rtl_tcp) from source - Python — runtime with
paho-mqttandpyyaml
Unraid Setup
Via Docker UI
- Go to Docker → Add Container
- Set Repository to
hameter:latest - Set Network to Host
- Set Extra Parameters to
--device=/dev/bus/usb - Add environment variables for
MQTT_HOST,METER_1_ID,METER_1_PROTOCOL, etc. - Start the container
USB Passthrough
The SDR dongle must be accessible inside the container. Use --device=/dev/bus/usb to pass the entire USB bus (simplest and most reliable across reboots).
Troubleshooting
No readings appearing
- Verify the SDR dongle is on a USB 2.0 port (USB 3.0 causes interference)
- Check that the antenna is attached
- Run discovery mode to confirm the SDR is receiving signals
- Check logs:
docker logs hameter
"usb_open error -3"
The kernel DVB driver is claiming the device:
rmmod dvb_usb_rtl28xxu
MQTT connection refused
- Verify Mosquitto is running:
docker ps | grep mosquitto - Check
MQTT_HOSTandMQTT_PORTare correct - If using Docker bridge networking, use the host IP (not
127.0.0.1)
Sensors not appearing in HA
- Verify the MQTT integration is configured in HA
- In HA, go to Developer Tools → MQTT → Listen and subscribe to
hameter/#to check if messages are arriving - Restart HA if sensors don't appear after the first discovery publish
Supported Meters
HAMeter supports any ERT meter that transmits on the 900 MHz ISM band:
| Protocol | Typical Manufacturer | Meter Type |
|---|---|---|
| SCM | Itron | Electric, Gas |
| SCM+ | Itron | Electric, Gas |
| IDM | Itron | Electric (with interval data) |
| R900 | Neptune | Water |
| R900BCD | Neptune | Water |
| NetIDM | Itron | Electric (net metering) |
License